<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-22 03-46-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 75 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 68 kHz 18926 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 5,76 dBr 7,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Creedence Clearwater Revival - Cotton fields "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 68 kHz MIN: 16 kHz % above 76 kHz: 0,0053 Acquired: 2025/02/22 3.45.07 Total samples: 18926 Equivalent time: 0:15:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 7,4 dBr MIN: 4,2 dBr AVE: 5,76 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/02/22 3.45.06) 03.32 03.34 03.36 03.38 03.40 03.42 03.44 0 2 4 6 8 Pm [dBr]